of the heads, the screen angle and flow direction, larger coarse debris is conveyed to the suction head (4) at the apex of the filter for evacuation. The debris evacuation pipe (7) is opened or closed by the built in valve (8). A differential pressure monitor (9) continuously assesses the amount of debris collected on the filter element and controls the operation of the debris evacuation apparatus.
When debris buildup creates the critical predetermined differential pressure across the filter, the evacuation sequence is initiated. The valve on the debris evacuation pipe automatically opens and the debris evacuation aparatus is actuated. The differential pressure at the heads creates the vacuum by which all debris is evacuated. The filter continues to clean itself until the monitor indicates a clean condition exists. The rotation of the conduit then is automatically stopped and the valve on the evacuation pipe closed.
The debris filter is controlled by a PLC based local control panel. The front of the control panel has a mimic diagram and all the controls and instrumentation required to operate the system. |